Instructions for the installer
34
5.5 Regulation of primary air
Referred to distance “A” in mm.
60 cm hobs with separable control panel.
Burner
G25
25 mbar
G30/G31
28/37 mbar
Auxiliary (1) 2.5 2.5
Semirapid r (2) 0.5 2.0
Semirapid l (3) 0.5 1.5
Rapid large (4) 0 2.5
Ultrarapid (5) 2.0 4.0
90 cm hobs with separable control panel.
Burner
G25
25 mbar
G30/G31
28/37 mbar
Auxiliary (1) 2.0 2.5
Semirapid (2) 0.5 2.0
Rapid (3) -0.5 1.5
Fish burner (4) -1.0 8.0
Ultrarapid (5) 1.5 5.5
60 cm hob with built-in control panel.
Burner
G25
25 mbar
G30/G31
28/37 mbar
Auxiliary (1) 2.5 2.5
Semirapid r (2) 0.5 2.5
Semirapid l (3) 0.5 2.0
Rapid medio (4) 0.0 2.5
Ultrarapid (5) 1.0 3.0
To identify the burners on your hob, refer to the drawings in point “6.3/6.4
Arrangement of burners on hob “